Dental Equipment & Supplies

Ipr Metal Plastic Strip Holder Orthodontic Handpiece

Tealth Foshan Medical Equipment Co., Ltd.
  • Condition:New
  • Certification:TUV, ISO, CE
  • Material:Aluminum
  • Light Way:Without Light
  • Water Way:Outer Channel
  • Usage Times:Non-Disposable

Base Info

  • Model NO.:L8-02
  • Application:Adult, Child
  • Loading Way:Gland Type
  • Head Diameter:Small Head
  • Exhaust Way:Exhaust Outside
  • Number of Holes:Four Holes
  • Connection:Without Quick Connector
  • Rotating Speed:Low-Speed Handpiece
  • Fit with:Ipr Handle Manual
  • Transport Package:Plastic Box
  • Specification:Aluminum, stainless steel
  • Trademark:TEALTH
  • Origin:China
  • HS Code:90184100
  • Production Capacity:50000PCS,Year

Description

Coarse

Single side

0.150

150μm single sided abrasive file for main reduction.

Double

0.300

300μm double sided abrasive file for high enamel reduction.



Fundamental function
Interproximal reduction contra angle handpiece (IPR) is the removal of small amounts of outer enamel tooth surface between two adjacent teeth. It is a means to acquire additional space to create ideal tooth alignment. Alternative names include: slenderizing, stripping, enamel reduction, and reproximation.
·Creates space to improve tooth alignment.
·Helps to improve the bite (the way your teeth fit together).
·Can increase the stability of the teeth, so they will retain their position long term.
·Can reduce "black triangles". This is created by the absence of gum tissue (gingival papilla) between teeth and gives the appearance of a dark space or hole.
·IPR in certain cases may alleviate the need for permanent tooth extractions.
·Note: IPR may also be used in conjunction with tooth extractions for reasons listed above.
·May help to improve the appearance of the teeth, reshaping them for a better esthetic outcome.

Ipr Metal Plastic Strip Holder Orthodontic Handpiece
Considerations
There are several factors an orthodontist must consider to determine if IPR is appropriate treatment.
Size and shape of the teeth.
The Position and alignment of the teeth.
The patient's facial features.
Existence of "black triangles" and need for esthetic improvement.

Risks
Generally, interproximal reduction will not lead to an increased risk of tooth decay or gum disease. Some patients may experience sensitivity to hot or cold. Overall, this procedure is a very safe and effective means of creating ideal tooth alignment.

Maintenance & Care
1.Please notice that check product appearance if it is obviously deformative or attached foreign matters.
2.It must be kept in high temperature autoclavable sterilizer with 15 mins , and then dried for 30 mins.
3.put the stripper in correct way with contra angle /manual grip .
4.the stripper will be placed on the interproximal teeth lightly stroke to cut and grind
5. in operation , if the stripper was broken or dropped at ground, should replace a new one in time .
6.After operation , the stripper should be cleaned up completely and put in dry conditions.